OM-258 035 Page 13
C. 208-230/400-460 Volts VRD Model*
Welding
Mode
Input
Power
Rated
Output
Welding
Amperage
Range
Maximum
Open-Circuit
Voltage
Amperes Input At Rated
Load Output, 50/60 Hz
KVA KW Dimensions
Net
Weight
208 230 400 460
Stick
(SMAW)
3-Phase
280 A @
31.2 VDC,
35 % Duty
Cycle
5-280 A
30 VDC
36.0 34.0 19.8 17.5 14.0 10.2
H: 13-1/2 in.
(343 mm)
W: 7-1/2 in.
(191 mm)
D: 18 in. (457
mm)
41 lb
(18.6 kg)
200 A @
28 VDC,
100 %
Duty Cycle
23.5 22.8 13.5 12.7 10.2 6.9
1-Phase
200 A @
28 VDC,
50 % Duty
Cycle
5-200 A
43.9 43.0 n/a n/a 9.9 6.5
150 A @
26 VDC,
100 %
Duty Cycle
35.0 32.9 n/a n/a 7.6 4.8
*Unit comes with Dinse weld output receptacles.
4-3. Environmental Specifications
IP Rating
IP23
This equipment is designed for outdoor use. It may be stored, but is not intended to be used for welding outside during precipitation unless
sheltered.
IP23 2014−06
4-4. Duty Cycle And Overheating
Duty Cycle is percentage of 10
minutes that unit can weld at rated
load without overheating.
If unit overheats, output stops, and
cooling fan runs. Wait fifteen
minutes for unit to cool. Reduce
amperage or duty cycle before
welding.
NOTICE − Exceeding duty cycle
can damage unit and void warranty.
5 Minutes Welding 5 Minutes Resting
200 A @ 50% Duty Cycle For Single Phase Operation
Overheating
0
15
A or V
OR
Reduce Duty Cycle
Minutes
280 A @ 35% Duty Cycle For 3 Phase Operation
221 587-A
3-1/2 Minutes Welding 6-1/2 Minutes Resting
% DUTY CYCLE
3 PHASE
OPERATION
SINGLE PHASE
OPERATION
0
10 20 30 40 50 60 70 80 90 100
50
100
150
200
250
280
300
WELDING AMPERES