OM-492 Page 28
Return To Table Of Contents
8-2. Routine Maintenance
Follow the storage procedure in the engine owner’s manual if the unit will not be used for an
extended period.
N
ote
Recycle
engine
fluids.
Stop engine before maintaining.
See also Engine Manual and Maintenance Label.
Service engine more often if used in severe condi-
tions.
* To be done by Factory Authorized Service Agent.
Every 8 h
Wipe Up
Spills.
Check Fluid
Levels. See
Section 5-2.
Drain Water From
Fuel System. See
Section 8-5.
FUEL
WATER
Full
Recovery Tank
Every 20 h
Check and clean optional
spark arrestor screen.
See Section 8-3.
Every 50 h
Clean and
tighten weld
terminals.
Check fuel lines
and connections.
See Section 8-5.
Every 100 h
Service air filter element.
See Section 8-4.
Check air cleaner
hoses for cracks
and loose clamps.
5/16 in.
(8 mm)
Check belt tension.
Clean and
tighten battery
connections.
Every 200 h
Change oil filter. See
Section 8-5 and
maintenance label.
Change oil. See Section 8-5
and maintenance label.
Replace primary
fuel filter. See
Section 8-5.
Check radiator
hoses and
clamps.
Replace unreadable
labels.
Every 400 h
Replace secondary
fuel filter. See
Section 8-5.

Table of Contents