Page #25 background imageLoading...
Page #25 background image
OM-356 Page 19
1
4-10. Placing Jumper Links
Ref. ST-801 973-B
Y Disconnect and lockout/tag-
out input power before
installing or moving jumper
links.
Check input voltage available at
site.
1 Jumper Link Label
Check label − only one is on unit.
2 Jumper Links
Move jumper links to match input
voltage.
Close access door, or go on to
Section 4-11.
3/8 in
Tools Needed:
230 VOLTS 460 VOLTS200 VOLTS
LL LL LL
S-083 566-C
2
230 VOLTS
LL
460 VOLTS
LL
S-010 587-B
575 VOLTS
LL
Do not overtighten
jumper link nuts.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Miller Syncrowave 350 LX  and is the answer not in the manual?

Miller Syncrowave 350 LX  Specifications

General IconGeneral
Amperage Range3 - 400 A
Max. Open-Circuit Voltage80 V
Input Frequency50/60 Hz
Rated Output300 A at 32 V, 60% Duty Cycle