59
Error list (PLC)
Error displayed Cause Measures
2
diameter Alarm
media installed on
UNWINDER unit is
too large.
1. Check the diameter of the media installed
in the UNWINDER.
The maximum diameter is φ1000mm.
If the diameter is over 1000mm, replace the
roll.
2. The tension bar falls too much during
jogging or feeding, and the media sags.
Readjust the media so that it does not sag.
3. Tap the [DETAIL] button in [SYSTEM
ALARM] of MPC, and tap the [CLEAR
ALARM] button.
4. If the Alarm is displayed again after tapping
the [CLEAR ALARM] button, turn off the
power of the internal PC and then the main
power of the machine in this order, and
then turn on again after a while.
5. If the Alarm appears again, contact your
dealer, our sales office, or call center.
(DRYERJET
Hot Door Alarm)
error on DRYERJET
1. Close the cover of the DRYERJET media
entrance.
2. Tap the [DETAIL] button in [SYSTEM
ALARM] of MPC, and tap the [CLEAR
ALARM] button.
3. If the Alarm is displayed again after tapping
the [CLEAR ALARM] button, turn off the
power of the internal PC and then the main
power of the machine in this order, and
then turn on again after a while.
4. If the Alarm appears again, contact your
dealer, our sales office, or call center.
2
Winder big
diameter Alarm
wound media on the
DRYERJET is too
large.
1. Check the diameter of the wound media.
The maximum diameter is φ500mm.
If the diameter is over 500mm, replace the
roll.
2. The tension bar falls too much during
jogging or feeding, and the media sags.
Readjust the media so that it does not sag.
3. Tap the [DETAIL] button in [SYSTEM
ALARM] of MPC, and tap the [CLEAR
ALARM] button.
4. If the Alarm is displayed again after tapping
the [CLEAR ALARM] button, turn off the
power of the internal PC and then the main
power of the machine in this order, and
then turn on again after a while.
5. If the Alarm appears again, contact your
dealer, our sales office, or call center.
Communication
between DRYERJET
1. Tap the [DETAIL] button in [SYSTEM
ALARM] of MPC, and tap the [CLEAR
ALARM] button.
2. If the Alarm is displayed again after tapping
the [CLEAR ALARM] button, turn off the
power of the internal PC and then the main
power of the machine in this order, and
Inverter Alarm
(Purge not
inverter error