3-8
Chapter 3 Setup
Change the pattern according to the scan
direction for printing.
The curing level differs depending on the pattern.
If you want to increase the level of ink curing, try
patterns one after another, starting with the
pattern with the highest level of curing.
If you want to decrease the level of ink curing, try
patterns one after another, starting with the
pattern with the lowest level of curing.
<Curing level>
Higher ++ > + > - > N/A lower
8
Press the key.
9
Press to select “Light Level”,
and press the key.
10
Press to set the level for the
intensity of the LED UV device, and press
the key.
Set value : Lv 1 to 10
Lowering the level decreases the intensity.
Raising the level increases the intensity.
Use Lv 5 to check the state of ink curing first, and
increase the value to strengthen the curing level
and decrease the level to weaken the curing level.
11
Press the key several times to
end the setting.
UV Mode Setup Procedure
Example: To weaken the curing level in bi-directional
printing
(1) In the "AUTO" settings, set "Light Adjust" in the
negative direction.
(2) Even when "-50%" is set for "Light Adjust", if the ink
curing level is strong, select "MANUAL".
Set F for "Pattern".
Set Lv5 for "Light Level".
(3) Check the state of ink curing.
If the curing level is strong: Reduce the light level.
If the curing level is weak: Increase the light level.
(4)
If an appropriate amount of light cannot be obtained even
by changing the value for "Light Level", change the pattern.
(5)
Repeat steps from (3) to (4) to set the pattern and light
level that helps obtain an appropriate amount of light.
Pattern
Scan direction
Curing level
Bi-directional Uni-directional
A++++
B+×+
C+× -
DN/A+ +
EN/A+ +
F+×N/A
+N/A
+ -