6.4.13 Suction FAN
Work Procedures
1. Turn off the main power supply and remove the power plug
from the main body.
2. Cut and remove the insulation lock tie.
3. Disconnect the connector from the junction cable.
4. Unscrew the screws, and remove the suction fan assy. from the
suction chamber BKT.
5. Reverse the disassembly procedure for reassembly.
Turn the main power OFF when turning the power OFF.
It is very dangerous if sleep mode functions mistakenly during the operation.
Screw(x3)
Suction chamber BKT
Connector
Suction fan assy.