4. Consumable Item Replacement
22
3
Open the maintenance covers.
4
Remove the mist filter box.
Push the tabs in the direction indicated by the arrow and slide to the side to remove.
Claw
Handle
Handle
Claw
5
Replace the mist filter with a new one.
6
Mount the mist filter box.
Insert until it clicks into place, and confirm that the tabs are engaged.
7
Once replacement is complete, close the cover, then press the [ENTER] key.
LED Glass Replacement
Replace with new LED glass if the ink hardens and the existing LED glass becomes dirty.
1
On the LOCAL mode screen, select [MENU] > [Maintenance], then press the [ENTER] key.
The Maintenance menu is displayed.
2
Select [Station] > [Carriage Out] > [Head Maint.], then press the [ENTER] key.
The carriage moves to the maintenance space.