10. Table of Error Codes
Error code Error source Remarks
Check tem
check
1.2.5.2. Thermal switch Brush 1/2
current consumption of brush motors; check
wiring of thermal switch (X8 and X9 plugs) of the
brush motors (series connection). Input A1.X9:1
and 7
1.2.6.1.
Blocking protection Brush 1/2 Electronic
protection of brush motors
Brush motors smooth running? Check current
consumption? 30A max. per motor
Group message all fuses on the A1
3.2.1.1. LDS defective
Is battery voltage identical to voltage at A1:X1
and A1.X2? (idle run and under load)
3.4.1.1. Drive rheostat
Check drive rheostat and wiring, is drive rheostat
detected at the controllers A1X4 connection?
3.4.1.2.
Off isle switch on during start up or Drive
Turn off off isle switch and restart machine
If error is permanent replace central controller
3.4.5.1. Drive motor overheated
Check thermal switch and wiring from drive
motor, X10 plug
36