74 TX3 Touch Screen Installation Manual
Touch Screen System and Setup
3.2.2 Touch Screen Field Wiring
Figure 63 shows the inputs and outputs for the Touch Screen.
Figure 63. Touch Screen wiring
Unless specified otherwise, all wiring is a maximum length of 1000 ft (304.8 m).
RS-485 maximum length: 4000 feet (1219.2 m).
The door strike power supply depends on the door strike power requirements.
See section 3.8.1 on page 88 for the maximum power supply wire distances.
mouse for
conguration
Cat 5
RS-485
communication
Shielded or unshielded
Cat 5 cable
P1264 IP camera
Network
Cat 5
Internet
and VOIP
Touch Screen
Door
Strike AC
or DC
Aux Door
Form C relay
contact
General
purpose output 1
(form C relay
contacts)
General
purpose output 2
(form C relay
contacts)
1 pair
18 AWG
1 pair
18 AWG
3 wires
22 AWG
3 wires
22 AWG
1 pair
18 AWG
12 VDC/0.5A
Aux power
Postal
Lock
Main Door
Sense
ver-ride
1 pair
22 AWG
1 pair
22 AWG
1 pair
22 AWG
General
purpose
input 1
General
purpose
input 2
1 pair
22 AWG
1 pair
22 AWG
INPUTS OUTPUTS
Electrical room
120 VAC
Power
supply
24 VDC
TX3-PS24-5A
NSL
Control
Unit
OR
Telephone outlet
Central oce line
T/R
T/R
Power
transformer
AC or DC Door
strike supply
Line1
1 pair
Telephone
wire
Electrical room
18 AWG
For gauges see Table 1