8 The Operation of GX Works2
8.6 Ethernet Diagnostics
110
FX3U-ENET-ADP User's Manual
[Description details of the result column]
1) Display of the PING test
a) Description of the IP address specification display
Pinging [IP address] with [Set size] bytes of data:
b) Example of IP address specification display
Pinging 192.168.0.3 with 32 bytes of data:
c) Description of the host name specification display
Pinging [Host name[IP address]] with [Set size] bytes of data:
d) Example of host name specification display
Pinging PLC1[192.168.0.3] with 32 bytes of data:
2) Description displayed on PING execution
IP address
Size of the received of the packet
Round trip time of the packet
Maximum lifespan of the packet
a) Description of the completion display
Reply from [IP address]:bytes=[Set size] time<1ms TTL=[Communication speed]
b) Example of completion display
Reply from 10.97.29.75:bytes=32 time<1ms TTL=64
c) Display when there is an error
Request timed out.
3) Description displayed on the reception end and the Cancel button click
Total packet transmission count
Success count
Failure count
Packet minimum round trip time
Packet maximum round trip time
Packet average round trip time
[Success/Transmissions]
The number of times of success and total number of times of a packet was sent are updated every time 1
packet is sent.