4.A2CCPU
--------------------
MELSEC·A
4.10.2
Setting
for
MELSECNETData Link
(1) Setting station
number
The station numbers are determined
according
to
the
routing of the
cable (coaxial
and/or
fiber-optic cables).
Determine
the
station numbers referring to
the
MELSECNET (II) Data
Link Reference Manual.
(2) Setting operation mode
This manual describes
the
setting only
for
the
self-loopback test mode
(link module independent test).
For other setting modes, refer to
the
MELSECNET (II) Data Link Refer-
ence Manual.
(3) Setting link parameters
Link parameter setting is necessary only
for
the A2CCPUP21/R21 which
is used as
the
master station.
For MELSECNET functions, processing methods, device allocation,
refer
to
the MELSECNET (II) Data Link Reference Manual.
IREMARKI
To
operalelhe
A2CCPUP21/R21 independenlly wilhoul connecling 10 Ihe MELSECNET
link:
(1) Set
the
mode
selection
switch
to "2"
(offline).
If
the
link
module
is used
without
setting
the
mode
to
"offline,"
the
"LINK
PARAMETER
ERROR"
occurs.
Sequence
program
operation can be
continued
correctly
even If
the
link
parameter error occurs.
I
(2) ON/OFF
slalus
of link
slalus
Indicaling LEOs is nol known nIhe link
cable
(coaxial cable,
fiber-optic cable) is not connected to the link module.
To
check
whether
the
link module is correct or faulty, execute
the
self-Ioopback
test
as in II
Section
4.10.4.
4-92