4.A2CCPU
--------------------
MELSEC-A
I
•
4.3.2
Fault detection with annunciator (F)
An annunciator (F) is used in a user's fault detection program.
If the annunciator is turned ON, associated control differs from
the
control
executed when an internal relay (M) or latch relay (L) is turned ON.
(a) If
the
annunciator is turned ON by
the
sequence program, the
special relay (M9009) is turned ON with the
number
of annunciator
which is turned ON stored in the special register (09009).
(b) Registers
09124
to
09132
store
the
number
of annunciators which
have been turned ON and those annunciator numbers.
The annunciator number stored in 09125
and
that
in
09009
are the
same number.
By monitoring M9009 and 09009 with an annunciator used in a fault
detection program. it is possible to check whether or
not
an error
has occurred and contents of
the
error.
-E;;~~;;I;;~--------····-----------······------------····--------
-----~
In
the
sequence program shown below, M9009 is turned ON when F5 is
turned ON and "5· is stored in 09009.
[Fault detection program]
L.
._
••• ••• •••
• __
••••••
• __
••••••••••
J
•
f--------1
SET
M9OO9
M9009
IOFF
~
ON I
(AnnunciatorON detactlon)
09009
O~5
(Number of annunciator
turned ON)
09124
o
~
1
(Number of annunciators
09125
turnad
ON)
O~5
09126
(Annunciator numbers
0
are stored In order that
annunciators are turned
09132
0
ON. (up to 8))
(1) Turning ON an annunciator
An OUT instruction (OUT F[ ]) or SET instruction (SET F[ ]) is used to
turn ON an annunciator.
(a) An annunciator can be turned ON/OFF by
turning
ON/OFF
the
input
conditions when an OUT instruction is used. The OUT instruction
is executed each scan.
Contents in M9009, 09009, and
09124
to
09132
do not change if
the annunciator is turned OFF using an OUT instruction.
4-47