APPENDICES
--------------------
MELSEC-A
Table
2.1
List
of
Special
Relays
(Continued)
_eel
Number Name De8crlptlon
Delell.
Speclel
Register.
Data
memory
OFF:
No
processing
• Clear all data memory (except special relays
M9016
clear
flag
ON
:
Output
clear
and
special
registers)
in
remote
run
mode
from
-
computer,
etc.
when
M9016
is 1.
• Clears all
unlatched
data
memory
(except
M9017
Data
memory
OFF:
No processing
special
relays
and
special
registers)
in
remote
-
clear flag ON
: Output
clear
run
mode
from
computer,
etc.
when
M9017
is 1.
M9020
User
timing
• Relay
which
repeats
ON/OFF
at
intervals
of
clock No. 0
predetermined
scan.
•
When
power
is
turned
ON or reset is
User
timing
performed,
the
clock
starts
with
OFF.
M9021
clock
No.1
02
scan
02
scan
• Set
the
intervels
of
ON/OFF
[DUTY]
====Ftj
instruction.
M9022
User
timing
-
clock
No.2
01 scan
~
HDUTY I
nl
I n2 I
M9020H
M9023
User
timing
clock
No.3
M9024
User
timing
clock
No.4
M9030
0.1
second
~
• 0.1
second,
0.2
second,
1
second,
2
second,
clock
seconds seconds
and
1
minute
clocks
are
generated.
•
Not
turned
ON
and
OFF
per
scan
but
turned
M9031
0.2
second
~e~ondsl
0.1
LJ
ON
and
OFF even
during
scan
if
clock
seconds
corresponding
time
has
elapsed.
• Starts
when
power
is
turned
ON
or
reset
is
1
second
0.5
105
LJ
performed.
M9032
-
clock
seconds seconds
M9033
2
second
~
clock
M9034
1
minute
~
clock
seconds 30
seconds
ON
•
Used
as
dummy
contacts
of
initialization
and
M9036
Normally
ON
OFF
application
instruction
in
sequence
program.
ON
•
M9036
and
M9037
are
switched
ON/OFF
M9037
Normelly
OFF OFF
Independently
of
the
CPU
RUN/STOP
switch
position.
M9038
and
M9039
are
switched
ON/OFF
in
accordance
with
the
RUN/STOP
switch
position,
l.e.
switched
OFF
when
the
-
ON
only
for
1
ON
~
1
scan
switch
is
set
to STOP.
When
the
switch
is set
M9038
scan
after
run
OFF
to
other
than
STOP,
M9038
is
only
switched
ON
during
1
scan
and
M9039
is
only
switched
~
1
scan
OFF
during
1
scan.
RUN
flag
(off
ON
M9039
only
for
1 OFF
scan
after
run)
M9040
PAUSE
enable
OFF:
PAUSE
disabled
•
When
RUN
key
switch
is at PAUSE
position
or
coil
ON
: PAUSE
enabled
remote
pause
contact
has
turned
ON
and
if
M9040
is ON,
PAUSE
mode
is
set
and
M9041 is
-
PAUSE
status
OFF:
During
pause
turned
ON.
M9041
contact
ON :
Not
during
pause
APP-7