APPENDICES
MELSEC·A
I
•
Table
3.1
List
of
Special
Registers
(Continued)
Stored
Related
Related
Number Name
Data
Explanation
Special
Special
Relay.
Register.
• Set
type
of remote
terminal
module
connected
to
the
A2C
with
0/1
for
each
bit.
0:
MINI
standard
protocol
1 : No protocol
See
Section
2.1.2 for details.
• Data
structure
0:
MINI
b15b14b13b12b11 b1Ot:eteb7
ee
b5 b4 b3b2b1 to
Remote
D9035
[)(J)(J
0/10/
0/10/10/10/10/
0/'10/110/10/10/1""
0/1
terminal
standard
09035
module
protocol
-
-
attribute
1
: No
protocol
~~,
Remote terminal No.2
Remote terminal No.3
Remote terminal No.13
RemoteterminalNo.14
Total
• Set the
total
number
of
stations
(1 to 64) of I/O
09036
number
1 to 64
modules
and remote
terminal
modules
connected
-
of
to the A2C.
-
stations
•
Default
is 64.
09038
Priority
• Set
priority
of "ERROR" LEO
lighting
(or
1 to 4
flickering)
for
error
indication
with
error
code
numbers.
•
Priority
setting
areas are as
follows.
LEO
indication
b15to
b12 b11 tc ea b7 to b4
bOtobO
-
-
09039
priority
Priority
5
D9038
Prio<l1y
• Priority 3 Priority 2 Priority 1
D9038
>< >< ><
Priority 5
• See
Section
4.2.8
for
details.
• Bits
which
correspond
to
1/0
modules
and
remote
terminal
modules
which
caused
communication
fault
are set at 1 (set).
(Bits
which
correspond
to
faulty
stations
are set at
1 if
communication
cannot
be
restored
to
normal
after
the
number
of retries set at 09174.)
•
Retained
at ON after
faulty
stations
have
returned
0:
to
normal.
*1
Normal
• Data
structure
09174
09056
Fauity
1:
1diteab15b14b13b12b11b10b9
b6 b7 b6 b5 b4 b3 b2 b1
bO
09196
to
station
Com-
M9067
to
09059
detection
munication
c,,,
..
ST. ST.
ST. ST.
ST. ST. ST. ST.
ST. ST.
ST. ST. ST. ST.
ST. ST.
09199
te 15
I.
13
'2
tt
'0
•
•
7
•
5
•
3
2 1
fault
ST. ST. ST. ST. ST. ST. ST. ST.
ST.
ST. ST. ST. ST. ST.
ST.
ST.
DO,",
32 31
eo es
28 Z7 28 25
2.
23 22
21 20
ts
te 17
DO'"
ST. ST.
ST. ST.
ST. ST. ST. ST.
ST.
ST. ST. ST. ST. ST.
ST. ST.
48
.7
48 45 44 43
42 41
40 30 30 37 36
35
34 33
DO'"
ST. ST.
ST.
ST. ST. ST. ST. ST.
ST. ST. ST.
ST. ST. ST.
ST. ST.
64 53
62
et
eo
ee se 51
ee 56 54 53
52
5'
50 48
•
Corresponding
bit
is set at 1 (set)
after
fuse
blow
of a
remote
1/0
module
is
detected.
APP
-13