4.A2CCPU
--------------------
MELSEC·A
(b) The watch
dog
timer setting must be greater
than
the
constant
scan
time setting.
If
the
watch
dog
timer setting is smaller than
the
constant scan time I
setting, a WOT error might occur.
The relationship between
the
constant scan time setting
and
the
watch
dog
timer setting is indicated below.
o< Constant scan time setting < WOT setting -1
(c) The set constant scan time must be greater
than
the
maximum scan
time of the sequence program.
If the sequence program scan time is
longer
than
the constant scan
time, the constant scan function is not performed correctly.
Constant
scan
Sequence
program
Constant scan setting
I I
0
10 20 30 40
10 20
30 40
10 20
30 40 10 20
I
I I I I
I
I I I
I I
I I I I
END 0
END
0
H-I
H
HI
Hf-
35 msec
I
5 mseo
35 msee
34 msee
I
8m
I
37 msec
2
eo 40
meec
40 msee
53
msec
sec
Scan
in which c10nstant scan is
not executed correctly
Fig.
4.12
Scan Time
Larger
than
Constant
Scan
Setting
(2) Setting for constant scan execution
(a) Constant scan execution
A constant scan time setting is written to
09020
using
the
sequence
program or
the
peripheral device.
(b) Constant scan not executed
The value
"0'
is written to 09020 using
the
sequence program or
the
peripheral device.
4-20
•