I
4.A2CCPU
--------------------
MELSEC·A
Table
4.9
Parameter
Setting
Range
(Continued)
~I.
Default
Peripheral Devlc
••
Value
Selling
Range
Refer to
Item
PU
GPP
HGP
PHP
MOlo M999
M/LJSO
10
2047
Setting for internal relay (M), latch
Ll000to
relay (L)
and
step
relay (S) L2047
Must
be consecutive numbers
0
0 0
0
-
NoneforS
for M, L, and S
Watchdog timer setting
200
msec
10 msec to
2000
msec
0
0 0
0
4.1.8
(10 msec increment)
100 msec : 256 points
TOto T199 (8 points increments) for 100
Timer setting
msec timers, 10 msee timers,
0
0 0
0 4.1.4
10 msee :
and 100 msec retentive
T200 to
timers.
T255 Must be consecutive numbers
XO
to Xl FF
Remote
RUN/PAUSE
contact setting None
(1
point
each
for
RUN/PAUSE
0
4.2.3
setting not possible for
-
0 0
4.2.4
PAUSE contact)
Fuse blown Continue
Operation
I/O verify error
Stop
mode
stan
Stop/continue 0 4.4.2
occurrence
of
Operation error Continue
-
0
0
error
Special
function
Stop
module
check
error
Operation
state just Output of operation state
STOP
....
RUN display mode before the before/after execution of
-
0 0
0
4.4.3
STOP
is operation
output
Print title registration
None
128 characters using all
-
0 0
0
4.4.4
MELSAP keys
Entry code registration None
Hexadecimal (0 to 9, A to F)
0
0 0
0
4.4.5
Maximum 6 digits
4-51