886
FX3G/FX3U/FX3UC Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
37 Operation of Special Devices (M8000 -, D8000 -)
37.1 Special Device List (M8000 -, D8000 -)
Timing Clock (Refer to Section 24.3 for details.) and Positioning [FX
3G
, FX
3U
and FX
3UC
PLCs]
(Refer to Positioning Control Edition for
details.)
[M]8330 DUTY (FNC186) instruction: Timing clock output 1 3
3
*1
D8330–––
[M]8331 DUTY (FNC186) instruction: Timing clock output 2
3
3
*1
D8331–––
[M]8332 DUTY (FNC186) instruction: Timing clock output 3
3
3
*1
D8332–––
[M]8333 DUTY (FNC186) instruction: Timing clock output 4
3
3
*1
D8333–––
[M]8334 DUTY (FNC186) instruction: Timing clock output 5
3
3
*1
D8334–––
[M]8335 Not used
–––
M 8336
*2
DVIT (FNC151) instruction:
Interrupt input specification function enabled
3
3
*3
D8336–––
[M]8337 Not used
–––
M 8338
*2
PLSV (FNC157) instruction:
Acceleration/deceleration operation
3 3
3
*1
–––
[M]8339 Not used
–––
[M]8340
[Y000] Pulse output monitor
(ON: BUSY/ OFF: READY)
3 3 3 –––
M 8341
*2
[Y000] Clear signal output function enable 3 3 3 –––
M 8342
*2
[Y000] Zero return direction specification 3 3 3 –––
M 8343 [Y000] Forward limit
3 3 3 –––
M 8344 [Y000] Reverse limit
3 3 3 –––
M 8345
*2
[Y000] DOG signal logic reverse 3 3 3 –––
M 8346
*2
[Y000] Zero point signal logic reverse 3 3 3 –––
M 8347
*2
[Y000] Interrupt signal logic reverse 3 3 –––
[M]8348 [Y000] Positioning instruction activation
3 3 3 –––
M 8349
*2
[Y000] Pulse output stop command 3 3 3 –––
[M]8350
[Y001] Pulse output monitor
(ON: BUSY/ OFF: READY)
3 3 3 –––
M 8351
*2
[Y001] Clear signal output function enable 3 3 3 –––
M 8352
*2
[Y001] Zero return direction specification 3 3 3 –––
M 8353 [Y001] Forward limit
3 3 3 –––
M 8354 [Y001] Reverse limit
3 3 3 –––
M 8355
*2
[Y001] DOG signal logic reverse 3 3 3 –––
M 8356
*2
[Y001] Zero point signal logic reverse 3 3 3 –––
M 8357
*2
[Y001] Interrupt signal logic reverse 3 3 –––
[M]8358 [Y001] Positioning instruction activation
3 3 3 –––
M 8359
*2
[Y001] Pulse output stop command 3 3 3 –––
Timing Clock (Refer to Section 24.3 for details.) and Positioning [FX
3U
and FX
3UC
PLCs] (Refer to Positioning Control Edition for details.)
[M]8360
[Y002] Pulse output monitor
(ON: BUSY/ OFF: READY)
3 3 3 –––
M 8361
*2
[Y002] Clear signal output function enable 3 3 3 –––
M 8362
*2
[Y002] Zero return direction specification 3 3 3 –––
M 8363 [Y002] Forward limit
3 3 3 –––
M 8364 [Y002] Reverse limit
3 3 3 –––
M 8365
*2
[Y002] DOG signal logic reverse 3 3 3 –––
M 8366
*2
[Y002] Zero point signal logic reverse 3 3 3 –––
M 8367
*2
[Y002] Interrupt signal logic reverse 3 3 –––
[M]8368 [Y002] Positioning instruction activation
3 3 3 –––
M 8369
*2
[Y002] Pulse output stop command 3 3 3 –––
*1. Available in Ver. 2.20 or later.
*2. Cleared when PLC switches from RUN to STOP.
*3. Available in the Ver. 1.30 or later.
Number and name Operation and function
Applicable model
FX
3G
FX3U
FX
3UC
Correspond
-ing special
device
FX
1S
FX
1N
FX
2N
FX
1NC
FX
2NC

Table of Contents