887
FX3G/FX3U/FX3UC Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
37 Operation of Special Devices (M8000 -, D8000 -)
37.1 Special Device List (M8000 -, D8000 -)
31
FNC275-FNC279
Data
Transfer 3
32
FNC280-FNC289
High Speed
Processing 2
33
FNC290-FNC299
Extension File
Register
34
FNC300-FNC305
FX
3U
-CF-ADP
35
SFC•STL
Programming
36
Interrupt
Function
37
Special Device
38
Error Code
A
Version Up
Information
B
Execution Times
Positioning [FX3U PLCs] (Refer to Positioning Control Manual for details.)
[M]8370 [Y003] Pulse output monitor
(ON: BUSY/ OFF: READY)
3
*2
–––
M 8371
*1
[Y003] Clear signal output function enable
3
*2
–––
M 8372
*1
[Y003] Zero return direction specification
3
*2
–––
M 8373 [Y003] Forward limit
3
*2
–––
M 8374 [Y003] Reverse limit
3
*2
–––
M 8375
*1
[Y003] DOG signal logic reverse
3
*2
–––
M 8376
*1
[Y003] Zero point signal logic reverse
3
*2
–––
M 8377
*1
[Y003] Interrupt signal logic reverse
3
*2
–––
[M]8378 [Y003] Positioning instruction activation
3
*2
–––
M 8379
*1
[Y003] Pulse output stop command
3
*2
–––
RS2 (FNC 87) [ch0] [FX3G PLCs] (Refer to Data Communication Edition for details.)
[M]8370 Not used
–––
[M]8371
*1
RS2 (FNC 87) [ch0] instruction: Send wait flag 3 –––
M 8372
*1
RS2 (FNC 87) [ch0] instruction: Send request 3 D8372
M 8373
*1
RS2 (FNC 87) [ch0] instruction: Receive complete
flag
3 D8373
[M] 8374 to [M] 8378 Not used
–––
M 8379
RS2 (FNC 87) [ch0] instruction: Time-out check
flag
3
–––
*1. Cleared when PLC switches from RUN to STOP.
*2. Available only when two FX
3U-2HSY-ADP units are connected to an FX3U PLC.
High Speed Counter Function (Refer to Subsection 4.7.5 for details.)
[M]8380
*3
Operation status of C235, C241, C244, C246,
C247, C249, C251, C252, and C254
3 3 –––
[M]8381
*3
Operation status of C236 3 3 –––
[M]8382
*3
Operation status of C237, C242, and C245 3 3 –––
[M]8383
*3
Operation status of C238, C248, C248 (OP), C250,
C253, and C255
3 3 –––
[M]8384
*3
Operation status of C239 and C243 3 3 –––
[M]8385
*3
Operation status of C240 3 3 –––
[M]8386
*3
Operation status of C244 (OP) 3 3 –––
[M]8387
*3
Operation status of C245 (OP) 3 3 –––
[M]8388 Contact for high speed counter function change
3 3 3 –––
M 8389 External reset input logic reverse
3 3 –––
M 8390 Function changeover device for C244
3 3 –––
M 8391 Function changeover device for C245
3 3 –––
M 8392 Function changeover device for C248 and C253
3 3 3 –––
*3. Cleared when PLC switches from STOP to RUN.
Interrupt Program
[M]8393 Contact for delay time setting
3 3 D8393–––
[M]8394
HCMOV (FNC189): Drive contact for interrupt
program
3 3 –––
[M]8395 Function changeover device for C254
3 –––
[M]8396
Not used
–––
[M]8397
–––
Number and name Operation and function
Applicable model
FX
3G
FX3U
FX
3UC
Correspond
-ing special
device
FX
1S
FX
1N
FX
2N
FX
1NC
FX
2NC