384
11 USING A DIRECT DRIVE MOTOR
11.3 Startup [A]
For absolute position detection system
The magnetic pole detection is required in the following cases.
When the system is set up (at initial startup of equipment)
When the Z-phase pulse of the direct drive motor manufactured by Mitsubishi Electric is not turned on at the system setup
(When the Z-phase pulse of the direct drive motor can be turned on manually, the magnetic pole detection is not required.)
After a direct drive motor is replaced
When [AL. 025 Absolute position erased] has occurred
Turn on the Z-phase pulse of the direct drive motor manufactured by Mitsubishi Electric in the JOG operation from the
controller after the magnetic pole detection.
1. Execute the magnetic pole detection. Refer to the following.
Page 372 Operation at magnetic pole detection
2. After the completion of the magnetic pole detection, change [Pr. PL01.0 Servo motor magnetic pole detection selection]
to "0" (magnetic pole detection disabled).
To omit magnetic pole detection at each power-on, after magnetic pole detection, turn on the Z-phase pulse of the direct drive
motor in the JOG operation and set [Pr. PL01.0] to "0" (magnetic pole detection disabled).
Servo parameter Description
PL01.0 Servo motor magnetic pole detection selection
0: Magnetic pole detection disabled
1: Magnetic pole detection at initial servo-on after cycling the power
5: Magnetic pole detection at every servo-on
Initial value: 1 (magnetic pole detection at initial servo-on after cycling the power)