• The contact data is an OR command. Accordingly, it becomes effective if the input on the main unit side 
is turned on.  Pay rigid attention.
The time required to transfer the contact data is as follows.
 Required time (ms) ≒ 100 + (Operation cycle in the master programmable controller)
• Because the high-speed parallel run mode is not supported, do not use it. Accordingly, 
   do not turn on the M8162.
The RS-485 board FX2N-485BD is required for the parallel wire link.  
Connect between the LE-40MTB-E and the wire link adaptor with the twisted pair cables. Perform the 
solid grounding at [ LFG ] in the LE-40MTB-E.  The allowable maximum cable length is 10 m.
To execute parallel link with the LE-40MTB-E, use the " PC-link " screen in " Other " on the engineer 
screen for setting.
4. Connection
LSA
LSB
LFG
SDA
RDA
SDB
RDB
SG
LE-40MTB-E
FX
2N
-485-BD
FX2N siries 
PC
Grounding resistance 
100Ω or less
Twisted pari cable
5. Setting
X
W
Reel diameter 
monitor or tension 
monitor screen. 
Complete 
initial setting
T T
T
T
P S S W O R D                
S E T → # # # # # S E T N U M B E R
A
S T T I N G S E L E C T M E N U B Y C U R S O R
 S W I T C H :  T E N S I O N :  S T R T S T P :  R E E L C H G :.
E
R E E L C H G :  R E E L :  M R N U :  O T H R E
S T T I N G S E L E C T M E N U B Y C U R S O RE
U N U S E :  F X - P A R A L :  N E T / I N I :  C C - L I N KM
P - L I N K S E L E C T P C - L I N KC
Select " FX-PARAL  "