2. Wiring and Connection
2 - 20
(1) Connection for semi-closed synchronous control (when using MDS-C1-V1 drive unit)
MDS-C1-V1
(Slave axis)
MDS-C1-V1
(Master axis)
Master axis
Slave axis
Detector cable
CNV12
MDS-B-SD
Signal distribution unit
CN2
CN2
CN2A
CN2B
CN2
CN3
Parameter settings
No. Abbrev. Parameter name Description
Set the detector type. (Refer to Chapter 3 Setup for details)
Master axis Speed command synchronous control : 00xx or 11xx or 22xx
Current command synchronous control : 00xx or 11xx or 22xx
SV025 MTYP Motor/detector type
Slave axis Speed command synchronous control : C0xx or C1xx or C2xx
Current command synchronous control : CCxx