6. APPLICATION OF FUNCTIONS
6 - 4
6.1.4 Control of simple cam function
The following three cam controls are available by setting the cam data and the cam control data with MR
Configurator2.
Cam
control
method
Description Actual movement
To-and-fro
control
Reciprocates
within a
specified cam
stroke.
t
t
Cam data and cam
control data
(Cam created by users)
Cam axis one
cycle current
value (Input)
Cam conversion
processing
Feed current
value (Output)
Feed
control
Updates a cam
standard
position per
cycle.
t
t
Cam data and cam
control data
(Cam created by users)
Cam standard
position
(First cycle)
Cam standard
position
(Second cycle)
Cam standard
position
(Third cycle)
Cam axis one
cycle current
value (Input)
Cam conversion
processing
Feed current
value (Output)
Linear
control
Performs linear
control to keep
the one-cycle
stroke ratio as
100%.
t
t
Cam data and cam
control data
(Linear cam: Cam No. 0)
Cam standard
position
(First cycle)
Cam standard
position
(Second cycle)
Cam standard
position
(Third cycle)
Stroke amount × 100%
Cam axis one
cycle current
value (Input)
Cam conversion
processing
Feed current
value (Output)