6. APPLICATION OF FUNCTIONS
6 - 12
3) Cam data start position
This setting is available only for the stroke ratio data type cam data.
The cam data position where the "cam axis one cycle current value" becomes "0" can be set as
the cam data start position.
The initial value of the cam data start position is "0". The cam axis is controlled with the cam data
from the 0th point (stroke ratio = 0%).
When a value other than "0" is set as the cam data start position, cam control is started from the
point where the stroke ratio is not 0%.
Set the cam data start position for each cam data within the setting range of "0 to (Cam resolution
- 1)".
t
t
Cam standard
position
(First cycle)
Cam standard
position
(Second cycle)
Cam standard
position
(Third cycle)
Feed current value
Cam axis
one cycle current value
Zeroth point Last point
Cam data
start position
4) Timing of applying cam control data
New values are applied to "Cam No." and "Cam stroke amount" when CAMC (Cam control
command) turns on.
"Cam standard position" is updated when "Cam axis one cycle current value" passes through the
0th point of the cam data.