7. PARAMETERS
7 - 16
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
CP CL
PA06
*CMX
Electronic
gear
numerator
(command
pulse
multiplication
numerator)
Set an electronic gear numerator. (Refer to section 7.3.1.)
To enable the parameter value in the positioning mode, turn off the power for 1 s or
more after setting and turn it on again. However, the time will be longer depending
on a setting value of [Pr. PF25 Instantaneous power failure tough drive - Detection
time] when "instantaneous power failure tough drive selection" is enabled in [Pr.
PA20].
To enable the parameter, select "Electronic gear (0 _ _ _)" of "Electronic gear
selection" in [Pr. PA21].
Set the electronic gear within the following range. Setting out of the range will trigger
[AL. 37 Parameter error].
1/27649 < CMX/CDV < 8484
Setting range: 1 to 16777215
1
PA07
*CDV
Electronic
gear
denominator
(command
pulse
multiplication
denominator)
Set an electronic gear denominator. (Refer to section 7.3.1.)
To enable the parameter value in the positioning mode, turn off the power for 1 s or
more after setting and turn it on again. However, the time will be longer depending
on a setting value of [Pr. PF25 Instantaneous power failure tough drive - Detection
time] when "instantaneous power failure tough drive selection" is enabled in [Pr.
PA20].
To enable the parameter, select "Electronic gear (0 _ _ _)" of "Electronic gear
selection" in [Pr. PA21].
Set the electronic gear within the range of [Pr. PA06].
Setting out of the range will trigger [AL. 37 Parameter error].
Setting range: 1 to 16777215
1