7. PARAMETERS 
7 -  39 
 
No./symbol/ 
name 
Setting 
digit 
Function 
Initial 
value 
[unit] 
Control 
mode 
CP CL 
PC14 
MOD1 
Analog 
monitor 1 
output 
_ _ x x  Analog monitor 1 output selection 
Select a signal to output to MO1 (Analog monitor 1). Refer to app. 8.3 of "MR-JE-_A 
Servo Amplifier Instruction Manual" for detection point of output selection. 
Refer to table 7.8 or 7.9 for settings. 
00h 
   
_ x _ _  For manufacturer setting  0h     
  x _ _ _    0h   
  
Table 7.8 Analog monitor setting value 
  
  
Setting 
value 
Item 
     
  
_ _ 0 0  Servo motor speed (±8 V/max. speed) (Note 1) 
     
  
_ _ 0 1  Torque (±8 V/max. torque) (Note 3) 
     
  
_ _ 0 2  Servo motor speed (+8 V/max. speed) (Note 1) 
     
  
_ _ 0 3  Torque (+8 V/max. torque) (Note 3) 
     
  
_ _ 0 4  Current command (±8 V/max. current command) 
     
  
_ _ 0 5  Command pulse frequency (±10 V/±4 Mpulses/s) 
     
  
_ _ 0 6  Servo motor-side droop pulses (±10 V/100 pulses) (Note 2) 
     
  
_ _ 0 7  Servo motor-side droop pulses (±10 V/1000 pulses) (Note 2) 
     
  
_ _ 0 8  Servo motor-side droop pulses (±10 V/10000 pulses) (Note 2) 
     
  
_ _ 0 9  Servo motor-side droop pulses (±10 V/100000 pulses) (Note 2) 
     
  
_ _ 0 D  Bus voltage (+8 V/400 V) 
     
  
_ _ 0 E  Speed command 2 (±8 V/max. speed) (Note 1) 
     
  
_ _ 1 7  Internal temperature of encoder (±10 V/±128 °C)  
     
  
Note   1.  The maximum speed of the HF-KN series servo motor is 4500 r/min and that of the HG-KN 
series is 5000 r/min. Please watch out when using an HG-KN series servo motor as a 
replacement for the HF-KN series servo motor because HG-KN series outputs 8 V at 5000 
r/min. HG-KN series servo motors output 8 V at 6000 r/min when you set "_ _ _ 1" in [Pr. PA28] 
to change the maximum speed to 6000 r/min. 
  
    2.  Encoder pulse unit 
  
    3.  The value in [Pr. PA11] or [Pr. PA12] whichever is higher is applied for the maximum torque. 
 
PC15 
MOD2 
Analog 
monitor 2 
output 
_ _ x x  Analog monitor 2 output selection 
Select a signal to output to MO2 (Analog monitor 2). Refer to app.  8.3 of "MR-JE-_A 
Servo Amplifier Instruction Manual" for detection point of output selection. 
Refer to [Pr. PC14] for settings. 
01h 
   
_ x _ _  For manufacturer setting  0h     
x _ _ _    0h   
PC16 
MBR 
Electromagne
tic brake 
sequence 
output 
  Set the delay time from when MBR (Electromagnetic brake interlock) turns off until 
when the base drive circuit is shut-off. 
 
 
 
Setting range: 0 to 1000 
0  
[ms] 
   
PC17 
ZSP 
Zero speed 
  Set an output range of ZSP (Zero speed detection). 
ZSP (Zero speed detection) has hysteresis of 20 r/min. 
 
Setting range: 0 to 10000 
50  
[r/min]