A - 6
CAUTION
Configure an electromagnetic brake circuit which is interlocked with an external emergency stop switch.
Servo motor
Electromagnetic brake
B
RA
Contacts must be opened
with the emergency stop switch.
Contacts must be opened when ALM
(Malfunction) or MBR (Electromagnetic
brake interlock) turns off.
24 V DC
U
To prevent an electric shock, injury, or fire from occurring after an earthquake or other natural disasters,
ensure safety by checking conditions, such as the installation, mounting, wiring, and equipment before
switching the power on.
(6) Maintenance, inspection and parts replacement
CAUTION
Make sure that the emergency stop circuit operates properly such that an operation can be stopped
immediately and a power is shut off by the emergency stop switch.
It is recommended that the servo amplifier be replaced every 10 years when it is used in general
environment.
When using a servo amplifier whose power has not been turned on for a long time, contact your local
sales office.
(7) General instruction
To illustrate details, the equipment in the diagrams of this Instruction Manual may have been drawn
without covers and safety guards. When the equipment is operated, the covers and safety guards must
be installed as specified. Operation must be performed in accordance with this Instruction Manual.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MR-JE series and is the answer not in the manual?

Mitsubishi MR-JE series Specifications

General IconGeneral
SeriesMR-JE
Safety FunctionSTO (Safe Torque Off)
TypeServo Drive
Encoder TypeIncremental encoder, Absolute encoder
Positioning FunctionPosition control
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overload, Overspeed, Encoder error, Regenerative error
Ambient Temperature0°C to 55°C
Vibration Resistance5.9 m/s² (0.6 G) in X, Y, and Z directions