5
2 Setup for Mounting
No. 99MBE095B
2
Setup for Mounting
This chapter describes the preliminary preparation for mounting this product onto the ma-
chine.
2.1
CheckingtheEquipmentModel
This document describes the models congured as shown below.
First, be sure to check which model will be used.
Eective length
Minimum resolution
3 : 0.05 (μm)
Interface specications
2. Siemens AG: DRIVE-CLiQ Interface
z
Interface specications and model
Applicable system Scale model
Siemens AG DRIVE-CLiQ interface ABS AT1123
y DRIVE-CLiQ Interface Specications
AT1123 supports the Siemens SINAMICS/SINUMERIK system.
The following software versions are supported:
y SINAMICS S120 and SINUMERIK series:
y SINAMICS S120 - V4.4 HF4 (04.40.23.15) or above for angular and linear encoders without "func-
tional safety".
y SINUMERIK 840D sl - V4.4 SP1 HF3 (04.04.01.03.005) or above for angular and linear encoders
without "functional safety".
y More information on DRIVE-CLiQ interface authentication and connecting cables can be found by
visiting the URL below.
y S120 Commissioning Manual
http://support.automation.siemens.com/WW/llisapi.dll/csfetch/68043633/IH1_
012013_eng_en-US.pdf?func=cslib.csFetch&nodeid=68043641&forcedownload=true
y MOTION-CONNECT DRIVE-CLiQ cables with M12 connector for direct measuring systems
http://support.automation.siemens.com/WW/view/en/60179485
y Encoders certied with DRIVE-CLiQ:
http://support.automation.siemens.com/WW/view/en/65402168
y Eective length
For the details of the eective length, refer to
"4 Specications" on page 29.