Loading...
24
3 Mounting onto the Machine
No. 99MBE095B
3.4
Connecting and Fixing the Signal Cable
3.4.1 Cable Connection and Operation Check
An example of the system conguration is shown below.
For the details of the cables, refer to
"4 Specications" on page 29.
Signal cable (option)
DRIVE-CLiQ connection cable (Prepared by the user)
Total length including signal cable, 29 m max.
SIEMENS
DRIVE-CLiQ-support
-
ed controller
Connect the cables and check operations
1
According to "3.4.2 Connecting the Signal Cable", connect the detector head and the signal cable.
After that, connect the signal cable to the SIEMENS DRIVE-CLiQ supported controller via DRIVE-
CLiQ connection cable. After completing the cable connections, make sure the screws on the connec-
tor plug of the signal cable are fully tightened.
Tips
When connecting additional cable at your need, make sure that the total length together with the
signal cable is 29 m at maximum.
2
Turn on the power and check the operations, functions, and performance of the scale.
NOTICE
After turning on the power, if the scale unit does not operate normally, check the connections rst. If the
scale does not operate normally even after the status of connections is checked and the power is supplied
again, investigate the cause, following the instructions in "5 Troubleshooting".
When checking the scale operations, be very careful that no cables are being pinched by the machinery.
When connecting the connectors, if swarf or other foreign objects are sandwiched in, that may cause mal-
functions.