34
4Specications
No. 99MBE095B
4.4.2 Alarm Code Content
The table below describes the linkage between the alarm code output from the controller and the
error inside the scale, as well as the cause and remedy for it.
SIEMENS
alarm code
Error inside the scale Cause and Remedy
y F3x137 y Overspeed
y Initialization error
y Hardware error
y Absolute value detection
error
y Transducer error
y Signal strength error
<<Cause>>
y The scale detected an error.
<<Remedy>>
y Check the mechanical xing state of the scale.
y Check the power supplied to the scale (power
ripple noise) and electrical noises.
y If there is no defect in the mounting condition
or the power-related state, the scale needs to
be replaced.
y F3x405 y Temperature error <<Cause>>
y The detector head detected a caution.
The position data is correct; however, it is
necessary to check the xing state and the
operating condition.
<<Remedy>>
y Is the ambient temperature of the detector
head over 60 °C?
=> If it is over 60 °C, check the driving condition
(speed, acceleration).
Tips
The SIEMENS alarm codes in the above table are displayed on the SIEMENS application (STARTER).