EasyManua.ls Logo

Mitutoyo ABSOLUTE ABS AT1123 - Precautions on Fixing the Cables

Mitutoyo ABSOLUTE ABS AT1123
63 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
27
3 Mounting onto the Machine
No. 99MBE095B
3.4.3 Precautions on Fixing the Cables
Be sure to note the following when xing the cables.
1
Perform wiring paying attention to the twisting or bends of the cables.
Note that the signal cable and DRIVE-CLiQ connection cable may malfunction due to noise, if bun-
dled with other cables that may cause electrical noise, or if they are located near a switching relay
dealing with a large current.
2
Use cable clamps or other fasteners to secure the cables.
Note especially the following when securing the cables:
NOTICE
Do not bend the cables.
Also, do not bend the cables beyond the bend radius range specied in "2.3.2 Bend Radius of the Signal
Cable".
Cable
Clamp
If the cables are going to be repeatedly bent, try to reduce stress applied to near the root of the clamping
part.
Clamp
Cable
Clamp
Cable
Clamp
Cushioning
(Machine)
Clamp
Fixing screws
Bushing
Cable
Clamp

Table of Contents