29
4Specications
No. 99MBE095B
4
Specications
Thischapterdescribesthespecicationsofthisproduct.
4.1
Specications
Items Description
Detection method Electromagnetic induction
Eective length: L
0
(mm)
24 types: 140,240,340,440,540,640,740,840,940,1040,1140,1240,1340,1
440,1540,1640,1740,1840,2040,2240,2440,2640,2840,3040
Section size 85x37 (mm)
Cable conguration
"2.3 Preparing the Signal Cable" on page 7
Position
Data
"0" position
"2.4.1 Datum Point Position for the Length Variation and ABS Origin
Point" on page 10
Resolution 0.05 μm
Indication accuracy (20 °C)
Eective length L
0
= 140 mm - 2040 mm : (3+5L
0
/1000) µm
Eective length L
0
= 2240 mm - 3040 mm : (5+5L
0
/1000) µm
Operation temperature/
humidity range
0 °C - 50 °C 20 % - 80 % RH (non-condensing)
Storage temperature/hu-
midity range
-20 °C - 70 °C 20 % - 80 % RH (non-condensing)
Power supply voltage 24 V DC (DRIVE-CLiQ:19 V - 30.8 V)
Maximum consumption
current
140 mA (Max)
Signal cable length 29 m at maximum (total of signal cable + DRIVE-CLiQ connection cable)
Maximum response
speed
3 m/sec
Coecient of thermal
expansion
≈8x10
-6
/K
Vibration resistance
(55 - 2000 Hz)
≤ 196 m/s
2
(20G) * With no error
Shock resistance
(11 ms 1/2 sin)
Eective length L
0
= 140 mm - 2040 mm : ≤ 343 m/s
2
(35G) * With no error
Eective length L
0
= 2240 mm - 3040 mm : ≤ 294 m/s
2
(30G) * With no error
Interface
■
AT1123
Siemens AG : DRIVE-CLiQ Interface
CE marking
EMC Directive EN61326-1
Immunity test requirement: Clause6.2 Table 2
Emission limit: Class B
RoHS Directive : EN50581