26
3 Mounting onto the Machine
No. 99MBE095B
2
Connect the signal cable to the detector head.
Connect it engaging the convex part of the cable outlet with the concave part of the connector.
A signal cable outlet seal is set between the detector head and the connector to ensure water-resis-
tance performance. When connecting the cable, make sure to conrm that a signal cable outlet seal is
set in the groove of the signal cable outlet.
Pay attention
to the shape
Connector xing screws M2.6:
Tightening torque: 0.2 N•m
Signal cable outlet seal
Signal cable
Signal cable outlet
3
If the signal cable outlet panel is removed in 1, set it in the opposite outlet.
Connect it engaging the convex part of the detector head with the concave part of the signal cable
outlet panel.
When connecting the cable, make sure to conrm that a signal cable outlet seal is set in the groove of
the detector head as in 2.
Signal cable outlet seal
Signal cable outlet panel
Countersunk screws M2.6x5, Tightening torque: 0.2 N•m
Detector head
Signal cable outlet
Although the detector head has a water-resistant structure, it may not function as it is supposed to if the tighten-
ing torque is insucient or if the signal cable outlet seal is improperly installed. To ensure waterproofness, make
connections according to the procedures described above.