© Copyright MOBA Mobile Automation Australia Pty Ltd
Working with Sensors
45
Load Settings
Hyraulic Settings
Sensor Settings
Exit
Select 'Sensor Settings' and press [ENTER]
button.
Select 'General Settings' and press [ENTER]
button.
HP Load Sensor
General Settings
Diagnostics
Exit
HP Load Sensor
Prop Range =+ 30.0%
Set Value = 50.0%
Delta Load = 10.0%
Delta T = 50ms
Trip Counter = 3
Exit
Select 'Set Value' and press [ENTER] button.
Use the [AUX] up or down buttons to adjust the
threshold.
Press [ENTER] button to exit editing mode.
Press [MENU] button to return to the standard
screen.
To set this threshold:
Press [MENU] button.
Select 'Accessory Settings' and press [ENTER]
button.
Select 'Sensor Settings' and press [ENTER]
button.
Setting the Load Override Deactivation Threshold
The Load Override Deactivation Threshold is given as a difference from the
Activation Threshold. This means that if it is set to 10%, the load override will
deactivate when the load is below the activation threshold by an amount of 10% of
maximum load.
Figure 5.4.3.1.4
Hydraulic Settings
Sensor Settings
Accessory Sensors
Joystick
LCD/LED Settings
Advanced Settings
Exit