Operation
05/06 AWB2724-1584GB
26
Choosing the main and system menu
Status display
Status display with time
Current
selection
flashes in
menu
1st menu level
Main menu
1st menu level
System menu
ALT
I 0.2..5 .
MC
MO 02:00 WS
Q ..34 . STOP
DEL
and
No
password
ESCESC
OK
PROGRAM
STOPå RUN
SET CLOCK
INFORMATION
SECURITY
SYSTEM
STARTPARAMETER..
MENU LANGUAGE...
Inputs
Memory card fitted
Weekday/Time Startup behaviour: WS = Warm start, CS = Cold start, ST = Stop
Outputs Operating state: RUN/STOP
On: 1, 2/Off: 3, 4…
Status display with date
Inputs
Weekday/date
Outputs
Advanced Status display
ID = Not implemented
I = Diagnostics inputs R = Not implemented
I13 = No meaning
I14 = 1, if no Link expansion
I15 = 1, if short-circuit on output Q1, Q2, Q3 or Q4
I16 = toggles if short-circuit on output Q5, Q6, Q7 or Q8
I 12 .
MC
MO 02:00 WS
Q ..34 . STOP
ALT
ESC
I 12
MO 01.04.2006 WS
Q ..34 . RUN
ALT
I 12 6.89..12
ID ..
I ..15.R . WS
Q 12345678 RUN