SR3 Type 1 Technical Manual TSP005.doc Issue 5.0 – Jan 2005
Money Controls 2005. All rights reserved.
Page 22 of 50
13.1 Decrease Security
Table 8: DIL Switches - Decrease Security
Value SW1 SW2 SW3 SW4 SW5 SW6
0 ON
Off Off Off Off
ON
+1 ON
Off Off
ON
Off
ON
+2 ON
Off
ON
Off Off
ON
+3 ON
Off
ON ON
Off
ON
+4 ON ON
Off Off Off
ON
+5 ON ON
Off
ON
Off
ON
+6 ON ON ON
Off Off
ON
+7 ON ON ON ON
Off
ON
13.2 Increase Security
Table 9: DIL Switches - Increase Security
Value SW1 SW2 SW3 SW4 SW5 SW6
0
Off Off Off Off Off
ON
-1
Off Off Off
ON
Off
ON
-2
Off Off
ON
Off Off
ON
-3
Off Off
ON ON
Off
ON
-4
Off
ON
Off Off Off
ON
-5
Off
ON
Off
ON
Off
ON
-6
Off
ON ON
Off Off
ON
-7
Off
ON ON ON
Off
ON
13.3 Reset Security
Set the DIL switches to either Increase Security 0 or Decrease Security 0. This will set the
sensor windows tweak value to 0 for the coin channel selected, i.e. the original programmed
sensor windows.