SR3 Type 1 Technical Manual TSP005.doc Issue 5.0 – Jan 2005
Money Controls 2005. All rights reserved.
Page 33 of 50
19.4 Set Bonus Award Level 1
Example:- To award 3 extra games when Bonus Level 1 is reached.
Switch off the power to the SR3.
Set the Program DIL switches to:-
SW1 SW2 SW3 SW4 SW5 SW6
ON ON ON
OFF OFF OFF
Switch on the power to the SR3.
Press the reject lever within 20 seconds.
The LED will turn RED.
Insert THREE of the programmed coins and check that they are accepted, i.e. 3 x £1, 1 x
50p + 1 x 10p + 1 x 20p etc.
Press the reject lever to return to normal operational mode.
The LED will turn GREEN.
Return ALL the DIL switches to the OFF position.
19.5 Set Bonus Award Level 2
Example:- To award 7 extra games when Bonus Level 2 is reached.
Switch off the power to the SR3.
Set the Program DIL switches to:-
SW1 SW2 SW3 SW4 SW5 SW6
ON ON ON ON
OFF OFF
Switch on the power to the SR3.
Press the reject lever within 20 seconds.
The LED will turn RED.
Insert SEVEN of the programmed coins and check that they are accepted, i.e. 7 x £1, 3 x
50p + 4 x 20p etc.
Press the reject lever to return to normal operational mode.
The LED will turn GREEN.
Return ALL the DIL switches to the OFF position.