SR3 Type 1 Technical Manual TSP005.doc Issue 5.0 – Jan 2005
Money Controls 2005. All rights reserved.
Page 36 of 50
20. Totalising Parameters
The following list of parameters are pre-programmed at MCL or using a ccProgrammer.
Further explanation of parameters:
Bonus Time Width:
Time out period after last coin entered while bonus is still valid.
Example: A bonus game is awarded at £1.00, and 80p has been entered. You must enter
another 20p or more before the Bonus Time Width period elapses in order to be awarded the
extra game.
Credit:
Credit attributed to coin 1 = Value of Coin 1 * Payment Scalar Factor
Table 13: Totalising Parameters
Parameter Range Meaning
Price 0-65,535 Required credit for game output
Value of coin 1 - 12 0- 65,565 Real coin value divided by payment scaling factor
Bonus level 1 0-65,565 Credit trigger level 1
Bonus award 1 0-127 No. Games awarded at trigger level 1
Bonus level 2 0-65,565 Credit trigger level 2
Bonus award 2 0-127 No. Games awarded at trigger level 2
Maximum game limit 0-127 Maximum no. of games limit
Coin meter value scalar 0-255 No. of pulses = credit/coin meter scalar
Bonus credit mode 0-1 0= disable 1=enable
Coin meter output enable 0-1 0= disable 1=enable
Manual credit mode 0-1 0= disable (Automatic) 1=enable (Manual)
Game pulse width 0-5
0= 75ms ON 75 ms OFF
1= 75ms ON 200ms OFF
2= 100ms ON 200ms OFF
3= 100ms ON 330ms OFF
4= 150ms ON 330ms OFF
5= 330ms ON 330ms OFF
Coin meter pulse width 0-3
0= 50ms ON 50 ms OFF
1= 100ms ON 100ms OFF
2= 150ms ON 150ms OFF
3= 200ms ON 200ms OFF
Bonus time width 0-15 Time in steps of 2.5secs
Totaliser mode 0 - 1 0 = disable 1 = enable
Default values = 0 (factory set if totaliser option not selected)