OPTIONS
Continuedonnextpageuuf6xgz,1683011490490-19-08MAY23-1/2
MSVersionASyncChartandSetting
InstructionsForTimingNon-StaggeredUnits
APY71695—UN—08MAY23
A—IndicatorTool#804060B—SeeInsetBelow
C—OffsetAngle
D—DiscAdjustingRod
TimingInstructions
1.Removemetercoversandinstallthetimingindicator
#804060onthemeterthatisbeingtimed.
2.Turnthemainhexshaftuntilalltheslackisremoved
fromthedrivechainsandthecenterofadischole
isalignedwiththeendofthesingulatoronthe
non-timeablemeter.
3.Locatetherequiredoffsetangleintheleftchartbelow.
NOTE:Ifconsecutivemeteresarebeingtimed,
theoffsetanglewillalternatebetweenthe
numberlistedinthechartandzerofor
eachsubsequentmeter.
4.Loosenthetoplockingnutonthediscadjustingrod.
5.Usingyourngers,pushthemeterdiscCCWto
removeanyslackwhileadjustingthelowernuton
adjustingrod,untilthedischolecentermatchesthe
requiredoffsetangleontheindicator.
6.Tightenthetoplockingnutonthetimingmeter,replace
thetimingindicatorwiththeoriginalsingulator,install
covers.
Dischole#Offsetangle
1810
24
7.5
306
36
5
404.5
603
*Theoffsetangleishalftheanglebetweentheseed
holes.Theformulatocalculatetheoffsetangleis:
Offsetangle=180÷(hole#)
60-1
062623