OPI-PulseNGKit-en-141106
Version: 2.01
Page 10 of 31
021,725,1*62/87,216
Operating Manual
PulseNG Kit
Connections
G1
-WZ.1
MONTR
- B2
1
SENSOR
IN5
IN4
IN3
IN2
IN1
OUT5
OUT4
OUT3
OUT2
OUT1
SENSOR
IBU-NG
9pol
SPECTRA
SPECTRA
-X1
-X2
19
17
15
13
11
9
7
5
3
1
3
2
1
PE
0 V DC
24 V DC
20
18
16
14
12
10
8
6
4
2
ETHERNET
USB
+24 V
+24 V
OUT1
OUT2
OUT3
OUT4
OUT5
IN1
IN2
IN3
IN4
IN5
0 V
L24
M24
Ax. x
R
021,725,1*62/87,216
Clip 9
24 V DC
LIMIT 1
LIMIT 2
LIMIT 3
Emergency cutout
Operative
Scenario Bit 1
Scenario Bit 2
Scenario Bit 3
MONITOR ACTIVE CONTROL. ON
ERROR RESET
0 V DC
Supply 24 V DC
Supply 0 V DC
PE
Figure 2: IBU-NG wiring diagram
Labeling Voltage Terminal Terminal PLC Outputs/Inputs
IN5 0 V 19 20 O Reset, delete errors
IN4 0 V 17 18 O Monitoring ON
IN3 0 V 15 16 O Bit 3 of scenario number
IN2 0 V 13 14 O Bit 2 of scenario number
IN1 0 V 11 12 O Bit 1 of scenario number
Out5 +24 V 9 10 I Ready
Out4 +24 V 7 8 I Terminal HW machine emergency stop
Out3 +24 V 5 6 I Limit 3 triggered
Out2 +24 V 3 4 I Limit 2 triggered
Out1 +24 V 1 2 I Limit 1 triggered
Table 3: IBU-NG labeling of wiring diagram