Tap Dismiss to dismiss the beacon.
NOTE: If there are multiple beacons, the radio displays the recent beacon received.
7.12
Fireground
The portable Fireground Communications System is designed for deployment at an incident scene.
It consists of central components that provide on-scene and in building radio coverage, and enhanced
personnel accountability and monitoring:
Your APX portable radios
Incident Management Software
Command Terminal
Radio Frequency (RF) Modem (Conventional Only)
Control Channel Radio (Trunking)
Optional Data Radio (Trunking)
Accountability Server (Trunking)
DVRS (Optional)
If you have a critical situation, you can press the Emergency button, which activates an alarm on the
Incident Management Software at the command terminal.
The command terminal receives the following status updates from your radio:
Turning the radio on and off
Automatic response to Polling
Response to Evacuation commands
Pressing the PTT button to make voice transmission
Sending an Emergency Alarm and Call
Entering or Exiting a Trunking Talkgroup
7.12.1
Entering Fireground Zone Channel (Conventional)
Procedure:
1 Upon powering up, one of the following scenarios occurs:
If the Fireground Zone Channel is set as default, you hear the gurgle tone and the radio
displays the home screen. You are in Fireground zone channel.
If the Fireground Zone Channel is set as default, but you hear a short, low-pitched tone,
the display shows Reg failed to indicate that the command terminal does not respond to
Fireground Zone Channel. Get a qualified technician for assistance.
If your home channel is not Fireground Zone Channel, toggle or change the radio zone
channel to Fireground Zone Channel.
If you are entering Fireground Trunking Talkgroup, upon powering up, ensure that the
Fireground Trunking Talkgroup is selected. The subscriber unit automatically appears on the
Incident Commander's terminal.
2 Listen for a transmission. Adjust the Volume Control Knob if necessary.
68012003048-GW
Chapter 7 : Advanced Features
71

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motorola solutions APX 6000XE and is the answer not in the manual?

Motorola solutions APX 6000XE Specifications

General IconGeneral
BrandMotorola solutions
ModelAPX 6000XE
CategoryTwo-Way Radio
LanguageEnglish

Related product manuals