LLRP Functionality 3 - 7
Configure LLRP
LLRP is in Server Mode by default. To configure LLRP to operate in Client Mode:
1. Tap the LLRP icon, then tap Configure LLRP.
Figure 3-10
LLRP Configuration Window
2. Select the Client Mode check box.
3. In the LLRP Port field, enter the port number on which the server waits for the LLRP client to communicate. The
default is 5084.
4. In the Server IP field, enter the server IP for the remote host to which LLRP communicates as a client.
5. Tap Apply.
6. Tap ok to close the window.
Version Information
To view software version information for the LLRP application, tap the LLRP icon, then tap Version Info.
Figure 3-11
LLRP Versions Window
This window displays the LLRP server application version, RFID library version, radio firmware version, and radio
OEM data version.
NOTE The version information in Figure 3-11 may differ from the information on the actual mobile computer
screen. Also, downloading data using LLRP scripts or the RFID_FLASH application updates the version
information.