RS-232 Interface 7 - 5
RS-232 Host Parameters (continued)
Selecting the ICL, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, Olivetti, Omron, OPOS/JPOS or Fujitsu host
type enables the transmission of code ID characters listed in Table 7-3. These code ID characters are not
programmable and are separate from the Transmit Code ID feature. Do not enable the Transmit Code ID feature
for these terminals.
Table 7-3
Terminal Specific Code ID Characters
ICL
Wincor-
Nixdorf
Mode A
Wincor-
Nixdorf
Mode B
Olivetti Omron
OPOS/
JPOS
Fujitsu
UPC-A A A A A A A A
UPC-E E C C C E C E
EAN-8/JAN-8 FF B B B FF B FF
EAN-13/JAN-13 F A A A F A F
Code 39 C <len> M M M <len> C <len> M None
Code 39 Full ASCII None M M None None M None
Codabar N <len> N N N <len> N <len> N None
Code 128 L <len> K K K <len> L <len> K None
I 2 of 5 I <len> I I I <len> I <len> I None
Code 93 None L L L <len> None L None
D 2 of 5 H <len> H H H <len> H <len> H None
GS1-128 L <len> P P P <len> L <len> P None
MSI None O O O <len> None O None
Bookland EAN F A A A F A F
Trioptic None None None None None None None
Code 11 None None None None None None None
IATA H<len> H H None None H None
Code 32 None None None None None None None
GS1 Databar Variants None E E None None None None
PDF417 None Q Q None None None None