EasyManuals Logo

Moxa Technologies ioLogik E1260 User Manual

Moxa Technologies ioLogik E1260
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #25 background imageLoading...
Page #25 background image
ioLogik E1200 Series Initial Setup
2-12
ATTENTION
Determine the maximum possible current for each power wire and common wire according
to its size and
maximum
allowable current spec. If the current exceeds the maximum rating, the wiring may overheat,
causing serious damage to your equipment. For safety reasons, we recommend an average cable size of 22
AWG. However, depending on the current load, you may want to adjust your cable size (the maximum wire size
for power connectors is 2 mm).
The power terminal block is located on the top panel of the unit. Connect the unit to a 12 to 36 VDC power
source as shown below.
Item Suggested Setting
Wire range 12 to 24 AWG
Screw Torque 7 lb-inch
Top View
If power is properly supplied, the Power LED will glow a solid amber color. Continue to configure the software
after you have finished installing the hardware.

Table of Contents

Other manuals for Moxa Technologies ioLogik E1260

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Moxa Technologies ioLogik E1260 and is the answer not in the manual?

Moxa Technologies ioLogik E1260 Specifications

General IconGeneral
TypeNetwork transmitter & receiver
Maximum transfer distance- m
Mean time between failures (MTBF)660260 h
CertificationUL/cUL Class I Division 2, ATEX Zone 2
Product colorSilver
LED indicatorsYes
Operating temperature (T-T)-40 - 167 °F
Cabling technology10/100Base-T(X)
Ethernet LAN (RJ-45) ports2
Input current0.110 A
AC input voltage24 V
Operating altitude0 - 2000 m
Storage temperature (T-T)-40 - 85 °C
Operating relative humidity (H-H)5 - 95 %
Weight and Dimensions IconWeight and Dimensions
Depth84 mm
Width27.8 mm
Height124 mm
Weight200 g