MSA
Technical Data
ALTAIR 4X
50
GB
* Certified for 0 - 25 vol.% O
2
The technical and performance specifications for the specialised EX-H and EX-M
sensor are the same as for the standard EX sensor.
Combustible O
2
*CO H
2
S
Measuring
range
0-100% LEL
0-5.00% Vol.CH
4
0-30% Vol. 0-1999 ppm
0-1999 mg/m
3
0-200 ppm
0-284 mg/m³
H
2
S-LC NO
2
SO
2
0-100 ppm 0-50 ppm 0-20 ppm
The ppm to mg/m³ conversion is calculated at 20° C and at atmospheric
pressure.