5 Technical Data
Weight 224 g (device with battery and clip)
Dimensions
(L x W x H)
112 x 76 x 33 mm – without fastening clip
Alarms Four gas alarm LEDs, a charge status LED, an audible alarm
and a vibrating alarm
Volume of
audible alarm
95 dBA at 30 cm typical
Display LCD display
Battery type Rechargeable Li polymer battery.
Li polymer battery must not be charged in Ex area.
Device run time 24 hours at 25 °C
Charging time 4 hours
The maximum safe area charging voltage U
m
= 6.7 VDC
Warm up time 2 min
Temperature
range
-20°C to 60°C
For measuring Carbon Monoxide & Hydrogen Sulfide
-20°C to 60°C
For measuring Oxygen, Methane, Propane, Pentane & Hydro-
gen - ATEX Certified Performance
-40°C to 60°C
For intrinsic safety
10 °C to 35 °C
while charging battery
Humidity range 15 % – 90 % relative humidity, non-condensing,
5 % – 95 % RH intermittent
Atmospheric
pressure range
800 to 1200 mbar
Ingress
protection
IP 67
Measuring
methods
Combustible gases: Catalytic sensor
Oxygen: Electrochemical sensor
Toxic gases: Electrochemical sensor
FASIT Srl - Via Orsera 13/b - 34145 TRIESTE - ITALY - Tel +39 040 825604 - www.fasit.it