OBSERVER-i HART
11
10.0 DEVICE SPECIFIC COMMANDS
The Device Specific commands are used strictly for the unique features of the Observer-i and at the
discretion of General Monitors, an MSA company. They are described here in Section 10.0 and are
summarized in Table 5.
10.1 COMMAND #132: DO ALARM TEST
This command turns Alarm test mode on/off.
Request Data Bytes
Byte
Format
Description
0
Unsigned 8
N/A
Response Data Bytes
Byte
Format
Description
0
Unsigned 8
N/A
Command-Specific Response Codes
Code
Class
Description
0
Success
No Command-Specific Errors
1 - 15
Undefined
16
Error
Access Restricted
17 - 127
Undefined