OBSERVER-i HART
13
10.4 COMMAND #141: SET ALARM RELAY CONFIGURATION
This command configures the relay settings.
Request Data Bytes
Byte
Format
Description
0
Unsigned-8
Alarm Hi Relay La/nL: 0 nL, 1 LA
1
Unsigned-8
Alarm Hi Relay En/dE: 0 dE, 1 En
Response Data Bytes
Byte
Format
Description
0
Unsigned-8
Alarm Hi Relay La/nL: 0 nL, 1 LA
1
Unsigned-8
Alarm Hi Relay En/dE: 0 dE, 1 En
Command-Specific Response Codes
Code
Class
Description
0
Success
No Command-Specific Errors
1 - 2
Undefined
3
Error
Passed Parameter too large
4
Undefined
5
Error
Too Few Data Bytes Received
16
Error
Access Restricted
17 127
Undefined
10.5 COMMAND #142 RESET EVENT HAPPENED FLAG
This command resets the Event Happened Flag.
Request Data Bytes
Byte
Format
Description
None
N/A
N/A
Response Data Bytes
Byte
Format
Description
None
N/A
N/A