EasyManua.ls Logo

MSA General Monitors OBSERVER-i - Command #164: Get Slow Changing Information; Command #165: Get Set up Information

MSA General Monitors OBSERVER-i
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OBSERVER-i HART
22
18-21
Float
Peak dB
Command-Specific Response Codes
Code
Class
Description
0
Success
No Command-Specific Errors
1-127
Undefined
10.19 COMMAND #164: GET SLOW CHANGING INFORMATION
This command is used to collect data from the Observer-i which is likely to change at a very slow rate.
Request Data Bytes
Byte
Format
Description
None
N/A
N/A
Response Data Bytes
Byte
Format
Description
0 - 1
Signed-16
Unit Temperature
2 - 5
Float
Supply Voltage
6 - 7
Signed-16
Reserve
Command-Specific Response Codes
Code
Class
Description
0
Success
No Command-Specific Errors
1-127
Undefined
10.20 COMMAND #165: GET SET UP INFORMATION
This command reads the setup information in the Observer-i.
Request Data Bytes
Byte
Format
Description
None
N/A
N/A
Response Data Bytes
Byte
Format
Description
0
Unsigned-8
N/A

Table of Contents