10.12 COMMAND #150: READ CLOCK
This command reads the internal real-time clock setting.
Request Data Bytes
Byte
Format
Description
0
N/A
N/A
Response Data Bytes
Byte
Format
Description
0 2
Date
Date: Day, Month, Year-1900
3
Unsigned-8
Hours
4
Unsigned-8
Minutes
5
Unsigned-8
Seconds
Command-Specific Response Codes
Code
Class
Description
0
Success
No Command-Specific Errors
1-127
Undefined
10.13 COMMAND #151: SET RUN TIME METER
This command sets the internal run time meter.
Request Data Bytes
Byte
Format
Description
0 3
Unsigned-32
Run Time Meter Value
Response Data Bytes
Byte
Format
Description
0 3
Unsigned-32
Run Time Meter Value
Command-Specific Response Codes
Code
Class
Description
0
Success
No Command-Specific Errors
1 4
Undefined
5
Error
Too Few Data Bytes Received