Accessing the Instrument Setup Mode
1. Press and hold the RESET button while turning the instrument ON.
• SETUP displays.
NOTE: In all of the following selections in this Set-up mode:
• Press ON/OFF to enter chosen value/go to the next page.
• Press the ON/OFF button to store the chosen value.
• Press RESET to decrement by one or toggle ON/OFF.
• Press and hold RESET to decrement by 10.
• Press PAGE to increment by one or toggle ON/OFF.
• Press and hold PAGE to increment by 10.
2. Enter password default "672".
3. Press ON/OFF to enter password.
• Correct Password: instrument continues/beeps three times.
• Incorrect Password: instrument enters the Measure mode.
4. Password ON/OFF (turns the password protection ON or OFF)
5. New Password Setup (changes the password)
6. Instrument Options Setup
• Safe LED ON/OFF
• Instrument Alarm Bypass Options Setup
• Visual alarm ON/OFF (red LEDs)
• Audible alarm ON/OFF (buzzer)
• Vibrator ON/OFF
• Backlight ON/OFF
• Backlight timer (10 seconds to 10 minutes)
• OP beep ON/OFF
• STEL/TWA ON/OFF
• Time (if data logging option installed)
• Date (if data logging option installed)
• CAL Due ON/OFF (if data logging option installed)
• CAL Due duration (1 to 180 days)
3-3